Send Message
Home ProductsIndustrial Centrifugal Fan

High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom

Certification
China Henan Xianrun Blower CO.,LTD certification
I'm Online Chat Now

High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom

High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom
High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom

Large Image :  High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom

Product Details:
Place of Origin: XINXIANG
Brand Name: XIANRUN BLOWER
Certification: CE, ISO 9001
Model Number: 9-19 SERIES
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: 50-50000
Packaging Details: WOODEN PACKING
Delivery Time: 5-45DAYS
Payment Terms: L/C, D/A, D/P, T/T
Supply Ability: 10000

High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom

Description
Voltage: 220V/380V/440V/480V/660V Power: 5 - 350KW
Warranty: 1 Year Color: Customer's Requirement
Air Volume: 800 - 90000m3 / H Blade Material: Stainless Steel,Cast Iron,Steel Plate,Q345 (16Mn) Manganese Steel
Material: Steel,316L,Carbon Steel /Stainless Steel,Q235 Type: Centrifugal Fan,Multi-wings Industrial Centrifugal Exhaust Blower Fan,centrifugal Blower,high Pressure Blower
Applications: Cooling Systems Name: Industrial Axial Flow Fan
Certification: CE, ISO 9001
High Light:

High Capacity Industrial Centrifugal Fan

,

Industrial Centrifugal Fan 560rpm

,

2900rpm Centrifugal Industrial Fans

High capacity exhaust fan inlet box mass flow rate portable blower fan centrifugal fan selection high efficiency fan

To ensure the operation effect of the centrifugal fan, there are four main points

 

First, environmental protection industrial centrifugal fans can be started at full pressure or step-down pressure, but when using full pressure start, we must ensure that the capacity of the grid is sufficient. Because the current at full voltage start-up is five to seven times the rated current, if the capacity of the grid is insufficient, it is necessary to use the form of buck start-up. This is a very important aspect, if the power grid is not sufficient to use full voltage start will certainly produce circuit failure.

 

Second, when the environmental protection industrial centrifugal fan is in the test run, we must carefully read the product manual, especially to check the circuit. Because when the centrifugal fan is in the test run, if there is a fault on the circuit, it will directly cause the fault of the fan.


Three, environmental protection industrial centrifugal fan in the test run, must not be less than two people. One person is to control the power situation, and one person to observe the operation of the fan. If there is an abnormal situation in the working process of the centrifugal fan, the fan must be stopped in time. Then check whether the fan is normal in all aspects of the data, when the inspection is completed, it takes at least five minutes to start again.

 

Fourth, even if the environmental protection centrifugal fan is in normal operation, it should also measure whether the input current of the fan is normal. If the test current exceeds the rated current, even if the fan is running, it should be stopped, and then measure all aspects of the data. Because there must be a reason for exceeding the rated current, it may affect the use effect of the fan.

 

The above four points can not only help the centrifugal fan to maintain a good operation effect, on the other hand, it can also realize the indirect protection of the centrifugal fan, prolong the service life, reduce the maintenance workload, but it does not mean that you can not do maintenance, regular maintenance or insist on.

 

High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom 0

 

High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom 1

 

High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom 2
 
Key Features 

  • Impeller diameter: 90~3500 mm 
  • Speed of mainshaft: 560~2900 rpm
  • Pressure range: 3000~25425 Pa
  • Flow range: 1297~83305 m3/h
  • Air Temperature: 20~1000 Celsius degree
  • Material: Cast Iron, Carbon Steel, Stainless Steel.

  • Efficiency: 80%-90%

Applications

  • Cement
  • Industrial boiler
  • Power generation
  • Chemical processing
  • Combustion-support
  • Cooling systems
  • Corrosive gas
  • Dryer
  • Dust collection
  • Forced draft 
  • Fume exhaust
  • General ventilation
  • Incineration
  • Induced draft

Please advise us the USAGE and following Parameter.Our engineering Dept will recommend the most suitable product for you.

 

Air volume/air flow   m3/h
Total pressure or static pressure   Pa
Medium temperature   °c
Voltage   V
Frequency   Hz
Altitude of operation place   m

 
 
High Capacity Industrial Centrifugal Fan 560rpm- 2900rpm Color Custom 3

Contact Details
Henan Xianrun Blower CO.,LTD

Tel: 13409216083

Send your inquiry directly to us (0 / 3000)